Terms beginning with I
I
IET 01
IET 01:2024 is a non-statutory IET standard and technical specification for Open combined Protective and Neutral conductor Detection Devices used with EV charging equipment. It sets out definitions, requirements and tests for how discrete or integrated OPDD functions should respond to open PEN conductor faults.
IK Rating (IK)
IK rating describes the level of protection an electrical enclosure provides against external mechanical impact. It is normally checked against mounting method, exposure, durability, access requirements and the conditions at the installation location.
Individual Supply Per Outlet
Individual supply per outlet means each charging outlet has its own dedicated electrical supply or separately protected feed. It is normally assessed alongside phase availability, circuit capacity, protective devices, cable sizing and DNO/site constraints.
Installation Location
The physical environment where a charger is installed, such as indoor, outdoor, wall, pedestal, car park, depot or public space. It is normally checked against mounting method, exposure, durability, access requirements and the conditions at the installation location.
Installation Manual
An installation manual provides instructions for mounting, wiring, commissioning, configuration and safe installation of a charger. It is normally checked against mounting method, exposure, durability, access requirements and the conditions at the installation location.
Integrated Payment Terminal
An integrated payment terminal is a built-in card or contactless payment device on the charger.
Interface
The controls, indicators or access methods a user interacts with on or through a charger. It is normally assessed alongside authorisation method, user experience, accessibility, payment flow and support requirements.
Internal PE Breakage
Internal PE breakage refers to a charger design where the charger has a means of interrupting or isolating the protective earth path internally as part of its response to a detected PEN fault condition.
IP Rating (IP)
IP rating describes the level of protection an enclosure provides against solid objects, dust and water ingress. It is normally checked against mounting method, exposure, durability, access requirements and the conditions at the installation location.
ISO 15118
ISO 15118 is the international vehicle-to-grid communication standard series covering EV-to-charger digital communication, Plug & Charge, smart charging and bidirectional charging functions. In the UK it is increasingly relevant to future-ready public, fleet and V2G-capable charging systems.
ISO 15118-1
ISO 15118-1 defines general information and use cases for the vehicle-to-grid communication interface. On EVCP Info, it links related terminology to the relevant regulatory, standards or compliance framework used by UK-focused audiences.
ISO 15118-10
ISO 15118-10 specifies requirements for wireless power transfer communication within the vehicle-to-grid communication framework. On EVCP Info, it links related terminology to the relevant regulatory, standards or compliance framework used by UK-focused audiences.
ISO 15118-2
ISO 15118-2 specifies network and application protocol requirements for EV-to-EVSE communication. On EVCP Info, it links related terminology to the relevant regulatory, standards or compliance framework used by UK-focused audiences.
ISO 15118-20
ISO 15118-20 is the second-generation vehicle-to-grid network and application protocol standard, extending support for advanced smart charging and bidirectional power transfer. On EVCP Info, it links related terminology to the relevant regulatory, standards or compliance framework used by UK-focused audiences.
ISO 15118-3
ISO 15118-3 covers physical and data link layer requirements for vehicle-to-grid communication. On EVCP Info, it links related terminology to the relevant regulatory, standards or compliance framework used by UK-focused audiences.
ISO 15118-4
ISO 15118-4 contains conformance test specifications for ISO 15118 network and application protocol requirements. On EVCP Info, it links related terminology to the relevant regulatory, standards or compliance framework used by UK-focused audiences.
ISO 15118-5
ISO 15118-5 contains conformance test specifications for the physical and data link layer of vehicle-to-grid communication. On EVCP Info, it links related terminology to the relevant regulatory, standards or compliance framework used by UK-focused audiences.
ISO 15118-6
ISO 15118-6 covers wireless communication general information and use cases within the vehicle-to-grid communication framework. On EVCP Info, it links related terminology to the relevant regulatory, standards or compliance framework used by UK-focused audiences.
ISO 15118-7
ISO 15118-7 defines wireless communication requirements for network and application layers in the vehicle-to-grid communication interface. On EVCP Info, it links related terminology to the relevant regulatory, standards or compliance framework used by UK-focused audiences.
ISO 15118-8
ISO 15118-8 covers wireless communication physical and data link layer requirements for vehicle-to-grid communication. On EVCP Info, it links related terminology to the relevant regulatory, standards or compliance framework used by UK-focused audiences.
IT Earthing
IT earthing is an arrangement where the supply has no direct connection to earth or is connected through a high impedance. It is normally assessed during product selection, circuit design, installation verification and maintenance of EV charging equipment.